DJWM68-C-2 (stainless steel) large diameter ultrasonic water meter
Model diameter | Common traffic Q3 |
DN50 | 25 m3 /h |
DN65 | 40 m3 /h |
DN80 | 63 m3 /h |
DN100 | 100 m3 /h |
DN125 | 160 m3 /h |
DN150 | 250 m3 /h |
DN200 | 400 m3 /h |
DN250 | 630 m3 /h |
DN300 | 1000 m3 /h |
Part (part) name | Model specifications | Main material | Remarks |
Measurement module | WM1058 | / | / |
Flow sensor | DJWM-P5-400 | Transducer: Piezoelectric ceramic | / |
Flow pipe section | DN50~DN300 | Cast steel | / |
Battery | ER18505/26500 | / | 3.6V |
Main technical indicators | |
Cumulative volume resolution | 0.01m 3 (when in use) 0.01L (when calibrating) |
Current traffic resolution | 0.01 m 3 /h (when in use) 0.01 m3 /h (when calibrating) |
Pressure resolution | 0.01 MPa |
Pressure measurement range | (0~1.6)MPa |
Quiescent operating current | < 6uA |
Battery life | >(6+1) years |
LCD display digits | 9 bits |
Temperature level | T30 |
Pressure level | MAP16 |
Pressure loss level | △p25, △p40 |
Environmental severity level | Class C |
Protection level | IP68 |
Accuracy level | Level 2 |
Electromagnetic environment level | E1 |
Installation method | horizontal or vertical |
Upstream flow field sensitivity level | U5 |
Downstream flow field sensitivity level | D3 |
Reverse flow | Measurable reverse flow |
Range ratio (Q3/Q1) | 125, 160, 200, 250, 400 optional |
Nominal diameter DN (mm) | Body length L (mm) | Flange outer diameter D2 (mm) | Threaded hole center diameter D1 (mm) | Connecting bolts | Flange thickness C (mm) |
50 | 200 | 120 | 125 | 4*M18 | 20 |
65 | 200 | 140 | 145 | 4*M18 | 20 |
80 | 225 | 180 | 160 | 8*M18 | 20 |
100 | 250 | 220 | 180 | 8*M18 | 22 |
125 | 250 | 250 | 210 | 8*M16 | 22 |
150 | 300 | 280 | 240 | 8*M20 | 24 |
200 | 345 | 335 | 295 | 12*M20 | 24 |
250 | 445 | 405 | 350 | 12*M24 | 26 |
300 | 500 | 460 | 400 | 12*M24 | 28 |