Product Description
- The water meter meets the requirements of GB/T 778-2007/ISO 4064:2005 standard.
- Wide range R=100/160.
- Meter reading data collection is accurate to 1 liter.
- Using copper ring cover, higher reliability (not the product of aluminum alloy cover on the market).
- Import-resistant nylon material is used instead of ordinary glass with a thickness of 11mm, and the maximum pressure resistance is 40kg, so it is not afraid of secondary water pressure.
- Freeze-proof, imported nylon material instead of glass will not freeze and crack within minus 30℃.
Technical parameters
item |
description |
Standard compliant |
GB/T 778-2007/ISO 4064:2005 etc. |
Case material |
ductile iron/stainless steel/food grade plastic/brass (optional) |
Water meter structure |
Wet non-magnetic, replaceable battery |
Temperature class |
T30 |
Gauge class |
Class 2 |
Traffic performance
Nominal Diameter(mm) |
Q3/Q1 |
Overload flow Q4
(m'/h) |
Common traffic Q3
(m'/h) |
Boundary flow Q2
(L/h) |
Minimum flow Q1
(L/h) |
15 |
80(100/160) |
3.125 |
2.5 |
50 |
31.25 |
20 |
80(100/160) |
5 |
4 |
80 |
50 |
25 |
80(100/125) |
7.875 |
6.3 |
126 |
78.75 |
Note: The actual dial mark shall prevail. Maximum allowable error:
a) The maximum allowable error in the low zone including the minimum flow (Q1) to excluding the boundary flow (Q2) is ±5%
b) The maximum allowable error from the boundary flow (Q2) to the high zone including the overload flow (Q4) is ±2%